top of page

Our sales policy for Mindray's area is limited to Karimnagar, Nizamabad, and Adilabad districts, as defined in the old Telangana districts map.

WATO EX-35 workstation

Anaesthesia Machine

WATO EX-35 workstation

The Mindray WATO EX-35 is a high-performance anesthesia workstation designed to meet the needs of modern healthcare settings. Here’s a detailed look at its features and specifications:

Key Features:

  • Touch-Screen Control: The WATO EX-35 features a 10.4-inch high-resolution touch-screen that displays up to three ventilation waveforms (EtCO2, Pressure, Flow & Volume), Spirometry Loop, and full gas monitoring simultaneously. This allows for direct access to all parameter controls and settings.

  • Smart Alarm System: The touch-responsive Smart Alarm system provides real-time detailed information, quickly alerting clinicians to adverse situations and supporting early resolution.

  • Enhanced Performance: The workstation supports an extensive range of features and functionalities, including an integrated plug-and-play AG Module (auto ID of 5 agents and N2O), and a multi-mode ventilator offering both controlled and support modes of ventilation.

  • Ventilator Drive Gas Auto Switch: This unique function ensures that the patient is ventilated without interruption at all times.

Physical Specifications:

  • Dimensions and Weight:

    • Height: 1410 mm

    • Width: 780 mm (excluding breathing system), 945 mm (including breathing system)

    • Depth: 690 mm

    • Weight: <145 kg (without vaporizers and cylinders)

    • Top Shelf Weight Limit: 30 kg.

Ventilator Specifications:

  • Modes of Ventilation: Manual/Spontaneous, Volume Control (VCV) with PLV function, Pressure Control (PCV), Synchronized Intermittent Mandatory Ventilation (SIMV-Volume Controlled and SIMV-Pressure Controlled), Pressure Support (PS) with apnea backup.

  • Patient Size: Adult, Pediatric, Infant.

  • Tidal Volume: 20~1500 mL (Volume Mode), 5~1500 mL (Pressure Mode).

  • Peak Gas Flow: 120 L/min.

Additional Features:

  • Fresh Gas Flow Optimizer: Indicates the recommended fresh gas flow to ensure safe low flow and minimize waste of anesthetic agents and medical gases.

  • Ergonomic Design: The WATO EX-35 is ergonomically designed to be positioned with ease and used for prolonged periods without causing unnecessary stress or fatigue.

The WATO EX-35 is designed to optimize the workflow of anesthesiologists while ensuring patient safety and comfort.

bottom of page